Powermaster Inverter Charger - High Frequency



Inverter Charger with Solar Regulator, ATS (UPS), Power Assist, Power Control, DC Battery Charger & LCD display. Connects directly with an off-grid solar system. 


                                                             

ST1500SSL & 3000SSL Inverter Charger

Inverter Charger with Solar Regulator, ATS (UPS), Power Assist, Power Control, DC Battery Charger & LCD display.


General--
Uninterrupted AC power (UPS function)
Power Control - Dealing with limited generator or shore side power
Power Assist - Boosting the capacity of shore or generator power
LCD display for parameter setting and error messages
Programming auxiliary relay (x 3)

Battery Charger--
Adaptive 4-stage charge characteristic: Bulk-Absorption-Float-Equalize
The right amount of charge: Variable Absorption Time
Preventing damage due to excessive gassing: The Battery Safe Mode
Less maintenance and aging when the battery is not in use: The Equalize Mode
2 outputs to charge 2 battery banks
To increase battery life: Temperature Compensation
Battery Voltage Sense


Description:
PURE SINE WAVE Inverter with ATS, Battery Charger and Solar Charge Controller
Connects with Solar system directly.


Model Number

DC Input

Continuous

wattage

Surge power

Battery charger

Starter charger

Solar charger

R/C

Port

BTS

Port

ST-1500SSL

12Vdc

1500W

3000W

70A

4A

40A

Y

Y

 

24Vdc

1500W

3000W

40A

4A

40A

Y

Y

 

48Vdc

1500W

3000W

20A

4A

40A

Y

Y

ST-3000SSL

12Vdc

3000W

6000W

140A

4A

40A

Y

Y

 

24Vdc

3000W

6000W

70A

4A

40A

Y

Y

 

48Vdc

3000W

6000W

40A

4A

40A

Y

Y


MODEL NO.
12 Volt System
24 Volt System
48 Volt System
ST-1500SSL-12X
ST-1500SSL-24X
ST-1500SSL-48X
ST-3000SSL-12X
ST-3000SSL-24X
ST-3000SSL-48X
GENERAL
Ventilation
Forced cooling
Forced cooling
Temperature
Operation
Storage
-20°C ~ +70°C
-25°C ~ +80°C
-20°C ~ +70°C
-25°C ~ +80°C
Protection
 
 
 a. Output short circuit
 b. Over load
 c. Battery voltage too high
 d. Battery voltage too low
 e. DC voltage ripple too high
 f. Temperature Sensor  
   Transformer
∨(105°C)
∨(105°C)
   Electronic & Powerstage
∨(70°C)
∨(70°C)
   BTS-3
∨(50°C)
∨(50°C)
Humidity
0~95% (non condensing)
0~95% (non condensing)
Power control Function
Power assist Function
Uninterrupted AC power
∨(less than 10 msec)
∨(less than 10 msec)
Adaptive 4-stage charge
Two output to charge 2 battery banks
Auxiliary Relay
X 3
X 3
Battery voltage sensor
Battery Temperature sensor (BTS-3)
Remote control port
INVERTER
Input Voltage Range (VDC)
9.5~16V / 19~32V / 38~64V
Output Voltage (VAC)
185~240 VAC / 90~120 VAC
Output Frequency
50Hz / 60Hz ± 0.1%
Output Waveform
Pure sinewave
Output Voltage THD
< 5%
Power Factor (All Loads)
No linger load, crest factor
3 : 1

Cont. Power Output (W)
Under 70°C (cosθ=1.0)

1500W
(No derate)
3000W
(No derate)
Cont. Power Output (W)
Over 70°C (cosθ=1.0)
0W
(Shutdown)
0W
(Shutdown)
Maximum Power (W)
3000W
6000W
Maximum Efficiency (%)
82/84/85
84/86/89
Zero-load Power (W)
12W
18W
CHARGER
Input Voltage Range (VAC)
200~250 VAC / 100~125 VAC
Input Frequency
45-55Hz / 55-65 Hz
Power Factor
1
Charge Characteristic
4-stage adaptive / Bulk-Absorption-Float-Equalize
Maximum DC Voltage Ripple (Vrms)
< 1.25 V
Charge Current House Battery (A)
70A/40A/20A
140A/70A/40A
Charge Current Starter Battery (A)
4A
Absorption Voltage Default (VDC)
14.4V / 28.8V / 57.6V
Float voltage Default (VDC)
13.8V / 27.6V / 55.2V
Equalize Voltage default (VDC)
13.2V / 26.4V / 52.8V
Output Charge Voltage (min ~ max)
8V~16V / 11V~32V / 22V~64V
Battery Temperature sensor
BTS-3
SOLAR CHARGE
System voltage ratings
12, 24, 48 Vdc
Current ratings-Battery Charge Control
40A
Accuracy
12/24V:≤0.1 % ± 50 mV
48V:≤0.1 % ± 100 mV
Min. voltage to operate
9V
Max. solar array Voc
140V
Max. operating voltage
68V
Total current consumption
While operating -25mA, at idle -3mA
High temp shutdown
90°C disconnect solar
70°C reconnect solar
Transient surge protection
 pulse power rating
4500 watts
 Response
< 5 nanosec
ENVIRONMENTAL
Ambient temperature
-40 to +45°C
Storage temperature
-55 to +85°C
Humidity
100% (NC)
AC INPUT SWITCH
AC IN Terminal Circuit Breaker
30A (110V) /15A (220V)
60A (110V) /30A (220V)
Switch-over Time 
 a. inverter to AC input
0 msec.
 b. AC input to inverter
0 msec.
Detection Time AC Input Fault
4 ~10 msec.
Trip Level AC Input to Inverter
90 VAC / 180 VAC
Trip Level Inverter to AC Input
94 VAC / 187 VAC
Min.~ Max. Frequency Range
45-55 Hz / 55-65 Hz
MECHANICAL
Cabinet / Protecting Class
Aluminum / IP20
Dimension (H X W X D)
Wall: 298 x 256 x 368
Table: 189 x 285 x 494
(mm)
Wall: 355 x 256 x 368
Table: 189 x 285 x 708
(mm)
Weight (kgs)
30 kgs
35 kgs