SUNNY TRIPOWER Inverters
Sunny Tripower 10000TL / 12000TL / 15000TL / 17000TL
The Tripower is in a class of its own. This inverter is packed with state-of-the-art technology and is designed for easy installation, high yield, and secure grid support. Thanks to its multi-string technology and the widest input voltage range, the three-phase inverter is suitable for every imaginable module configuration. In addition, it is highly flexible in terms of the plant design - from 10 kW up to the megawatt range.
The Sunny Tripower presently fulfills the BDEW guideline requirements (medium voltage guideline), and in so doing, it participates in reliable grid management. A comprehensive security concept encompassing, among other things, string failure detection, electronic string fuses, and an integrable surge protection device type II, providing the highest level of availability and reducing plant costs.

- Maximum efficiency of 98 %
- Highest yields through OptiTrac and OptiCool
- Compatible with the BDEW guidelines
- Integrated ESS DC load disconnecting unit
- Electronic String Fuse and String Failure Detection
- String Current Monitoring
- DC Surge Protection Device (type II) can be integrated
- DC input voltage of up to 1000 V
- Flexible system design using two separate step-up converters
- Three-phase feed-in
- Cable connection without tools
- Innovative DC plug system
- Convenient wiring compartment
- Bluetooth Communication
| Input (DC) | Sunny Tripower 10000TL | Sunny Tripower 12000TL | Sunny Tripower 15000TL | Sunny Tripower 17000TL | | Max. DC power (at cos φ = 1) | 10.4 kW | 12.5 kW | 15.6 kW | 17.6 kW | | Max. DC voltage | 1000 V | 1000 V | 1000 V | 1000 V | | PV-voltage range, MPPT | 150 – 800 V | 150 – 800 V | 150 – 800 V | 150 – 800 V | | Max. input current (input A / input B) | 22 A / 11 A | 22 A / 11 A | 33 A / 11 A | 33 A / 11 A | | Number of MPP trackers | 2 | 2 | 2 | 2 | | Max. number of parallel strings (input A / input B) | 4 / 1 | 4 / 1 | 5 / 1 | 5 / 1 |
| Output (AC) | | | | | | Nominal AC ouput | 10 kVA | 12 kVA | 15 kVA | 17 kVA | | Max. AC power | 10 kVA | 12 kVA | 15 kVA | 17 kVA | | Max. output current | 16 A | 19.2 A | 24 A | 24.6 A | | Nominal AC voltage | 3 / N / PE, 230 / 400 V | 3 / N / PE, 230 / 400 V | 3 / N / PE, 230 / 400 V | 3 / N / PE, 230 / 400 V | | AC grid frequency (self-adjusting) / range | 50 Hz / 60 Hz / ± 4.5 Hz | 50 Hz / 60 Hz / ± 4.5 Hz | 50 Hz / 60 Hz / ± 4.5 Hz | 50 Hz / 60 Hz / ± 4.5 Hz | | Phase shift (cos φ), adjustable | 0.8 leading ... 0.8 lagging | 0.8 leading ... 0.8 lagging | 0.8 leading ... 0.8 lagging | 0.8 leading ... 0.8 lagging | | AC connection | Three-phase | Three-phase | Three-phase | Three-phase |
Data Sheet |