Phocos CXN Charge Controller

Phocos CXN Charge Controller (10 – 40 A)
- Charge and discharge status display
- Acoustic load disconnect pre-warning
- Load status indication
- Choose between 5 load disconnect algorithms
- Boost/absorption/float PWM-regulation (series type)
- Integrated temperature compensation
- Covered terminals (up to 16 mm2 wire size)
- Full solid-state protection
Phocos CXN Charge Controller
The battery state of charge is clearly displayed with a bar chart, as well as energy flows from and to the battery and the load status (e.g. overload, load short circuit). The deep discharge protection function can be set up to three different modes: voltage controlled, SOC controlled or adaptive (fuzzy logic).
Acoustic warnings are built in, also a programmable nightlight function. As an accessory we can provide an Excess Energy Management output to control special Phocos appliances like the SF solar refrigerators/coolers. The compact case design is prepared for DIN rail mounting (mounting device available as an accessory).
The CX series is a sophisticated solar charge controller family with exceptional features in this price range. Beside a perfect PWM regulation with integrated temperature compensation the controllers provide extraordinary display, programming and safety functions.
| Type | CX 10 CX 20 CX 40 |
|---|---|
| System voltage | 12/24 V auto recognition |
| Max. charge/load current | 10 A 20A 40A |
| Float charge | 13.7/27.4 V (25 °C) |
| Main charge | 14.4/28.8 V (25 °C), 30 min. (daily) |
| Boost charge | 14.4/28.8 V (25 °C), 2 h activation: battery voltage <12.3/24.6 V |
| Equalization | 14.8/29.6 V (25 °C), 2 h activation: battery voltage <12.1/24.2 V |
| Deep discharge protection: State of charge dependent Voltage dependent Adaptive Reconnect level |
A: 11.4 – 11.9 V /22.8 – 23.8 V B: 11.0 – 11.75 V / 22.0 – 23.5 V A: 11.0/22 V B: 11.5/23 V 11.0 – 12.2 V / 22.0 – 24.4 V 12.8/25.6 V |
| Overvoltage protection | 15.5/31.0 V |
| Undervoltage protection | 10.5/21.0 V |
| Max. panel voltage (Overvoltage protection by varistor) | 30 V in 12 V system 50 V in 24 V system |
| Temperature compensation (Charge voltage) | −25 mV/K at 12 V −50 mV/K at 24 V |
| Self consumption | < 4 mA |
| Grounding | positive grounding possible |
| Ambient temperature | −20 to +50 °C |
| Max. height | 4,000 m above sea level |
| Battery type | lead acid (GEL, AGM, flooded) |
| Wire cross section | < 16 mm2 |
| Weight | 168g 179g |
| Dimensions (W xH x D) | 92 x 93 x 38 mm |
| Type of protection | IP22 |