SMA Sunny Backup Inverters

What happens if your PV-installation disconnects from the grid in the event of a blackout?  Should this ever happen your installation will not produce any more electricity for grid feeding or to your supply for your consumers in their properties.

SMA have a solution with the Sunny Backup-System: As an add-on for the PV-system it automatically switches the system to island power supply in the case of a grid failure.

You can equip every SMA inverter-operated system as well as new systems with a Sunny Backup-System. A Further advantage: Due to the integration of the PV system, a small and therefore low-cost battery can be fitted, as it is usually only needed to bridge the night hours.

The Sunny Backup-System is designed as pre-configured sets for all power ranges from 1 up to 100 kW. Easy to install and easy to upgrade when required.

                                                                                                                                                                                                           

 SUNNY BACKUP Set M/L/XL

Best performance, greatest user benefits and lowest investment and operating costs: in comparison with conventional emergency power systems, the Sunny Backup System scores well. As an add-on to the PV system, the Sunny Backup automatically switches to off-grid supply within approx. 20 milliseconds in the event of a grid failure. New and existing PV-plants can be equipped with the Sunny Backup – without affecting system efficiency. And the best part: due to the integration of the PV system, a small and therefore low-cost battery can be implemented as it is usually only needed to bridge the night hours.

Island electricity for commercial PV systems up to around 100 kW. For a safe supply to important consumers.

  • Nominal AC PV-power: 5.7 kW / 30 kW / 110 kW
  • Nominal Backup-power: 5 kW / 15 kW / 60 kW
  • Nominal battery voltage: 48 V

Output (loads) Backup Set M Backup Set L Backup Set XL
Nominal power / current during grid operation 8 kW / 35 A44 kW / 3 x 63 A110 kW / 3 x 160 A
Backup power (continuous / 30 min / 1 min)5 kW / 6.5 kW / 8.4 kW15 kW / 19.5 kW / 25.2 kWup to 60 kW / 78 kW / 100 kW
Number of phases (grid operation / backup operation)39.816,003 / 3 3 / 3
Voltage (range)230 V (172.5 – 264.5 V)230 V (172.5 – 264.5 V)230 V (172.5 – 264.5 V)
Frequency (range)50 Hz (45 to 65 Hz)50 Hz (45 to 65 Hz)50 Hz (45 to 65 Hz)
Permitted grid structure (grid side / load side)TN-C / TN-STN-C / TN-STN-C / TN-S
Typical interruption time in the event of power outage20 ms20 ms20 ms

Input PV system   
Nominal AC PV output / current5.7 kW / 25 A30 kW / 3 x 44 A110 kW / 3 x 160 A
Compatible PV invertersall SB and SMC 4600Aall SB and SMCall SB and SMC
Input battery   
Nominal voltage / number of blocks48 V / 4 x 12 V48 V / 8 x 12 V48 V / 32 x 12 V
Type / energy / capacity per blockAGM/6.8 kWh/142 AhAGM/13.6 kWh/142 AhAGM/54.4 kWh/142 Ah
Service life (according to Eurobat)> 12 years> 12 years> 12 years

Sunny backup data 1

Sunny backup data 2

 Sunny Backup Set S

Innovative electricity supply for home owners: as on add-on to the PV system, the Sunny Backup Set Small switches to off-grid mode within 50 milliseconds. For winter or summer: owners of small or medium-sized PV systems with inverters from SMA can supply the important loads self-sufficiently in the event of a power failure. The affordable complete solution is not only suitable for new solar power systems; existing PV systems can also be retrofitted with the certified Sunny Backup System without difficulty.

Island electricity for single family homes. Easy, cost effective integration into new and existing systems up to around 4.6 kW.

  • Nominal AC PV-power: 4.6 kW
  • Nominal Backup-power: 2.2 kW
  • Nominal battery voltage: 24 V

Output (loads)Sunny Backup Set S
Nominal power / current during grid operation 5.7 kW / 25 A
Backup power (continuous / 30 min / 1 min)2.2 kW / 2.9 kW / 3.8 kW
Number of phases (grid operation / backup operation)1 / 1
Voltage (range)230 V (172.5 – 264.5 V)
Frequency (range)50 Hz (45 to 65 Hz)
Permitted grid structure (grid side / load side)TN-C / TN-S
Typical interruption time in the event of power outage50 ms

Input PV system 
Nominal AC PV output / current4.6 kW / 20 A
Compatible PV invertersAll Sunny Boy inverters *
Input battery 
Nominal voltage / number of blocks24 V / 2 x 12 V
Type / energy / capacity per blockAGM / 3.4 kWh / 142 Ah
Service life (according to Eurobat)> 12 years

Sunny backup data 1         Sunny backup data 2

                                                                                                                                                           